| Sterilight's PLATINUM UV disinfection systems offer
simple, safe and effective disinfection. If waterborne pathogens,
including bacteria, virus, protozoa and others are a concern, Sterilight
PLATINUM UV is the answer!
Disinfection using ultraviolet (UV) light is fast becoming the
ecological choice in disinfection techniques. UV effectively destroys
microbial contaminants without adding anything to the water. Unlike
chlorine where there is a possibility of potentially harmful by-products
created during its disinfection process, UV creates no residual
by-products. The process is quickly completed within the confines
of the reactor. Unlike chlorine and ozone treatments, no external
tanks are required and no hazardous chemicals need to be handled.
- flow rates of up to 60 gpm
- high output coated UV lamps
- 304 stainless steel axial flow reactors
- electronic controller with graphical Smart-Switch™ interface
- 2-stage flow pacing with Flow-Pace™ UV sensor
- over molded connector with built-in safety interlock switch
- > 99.99% destruction of bacteria, virus, and protozoan cysts
(Giardia lamblia & Cryptosporidium) at rated flow
- natures way to protect your water without the addition of harmful
chemicals
- seven year warranty on reactor chamber for unparalleled protection
- product certified by CSA (C US) and to CE standards
| Rated
Flow Rate |
16 mJ/cm² |
227.1 L/min
(60 gpm)
(13.6 m³/hr.) |
| 30 mJ/cm² |
158.9 L/min
(42 gpm)
(9.5 m³/hr.) |
| 40 mJ/cm² |
117.3 L/min
(31 gpm)
(7.0 m³/hr.) |
| UV Intensity Monitor |
|
| Flow Pacing |
|
| Elapsed Time Meters
|
Day Counter |
|
| Total Running Hours |
|
| Dry Contacts |
|
| Safety Interlock
|
|
| Lamp Replacement Reminder |
|
| Diagnostic Check |
|
| Communication Port |
|
| Reactor Chamber
Material |
304 SS |
| Electrical |
Volts |
90-265V/ 50-60 Hz |
| Power Consumption |
80W |
| Lamp Watts |
80W |
| Maximum Operating
Pressure |
8.62 bar (125 psi) |
| Ambient Water Temperature |
2-40°C
(36-104°F) |
| Maximum Ambient
Temperature |
50°C
(122°F) |
| Rated Service Life of Lamp |
9000 hours |
| Dimensions |
Chamber (L x D) |
1000.8 x 89 mm
(39.4 x 3.5") |
| Controller (L x W x H) |
254 x 114 x 53 mm
(10.8 x 4.5 x 2") |
| Shipping Weight |
10.9 kg (24 lbs.) |
| Inlet/Outlet Port Size |
1" MNPT |
| |
|
| |
UVSP740-HO/2A |
Sterilight Platinum Ultraviolet |
UV Lamp Replacement
UV lamps should be replaced every 9,000 hours (yearly)
| |
|
| |
S740RL-HO |
Replacement UV lamp for UV SP740-HO/2A |

|
|
|